lftborder
rtborder

Low-pressure compressed natural gas dryer

LCNG = Low-pressure compressed natural gas dryer

 

Dual Tower Continuous Duty Purifier

Pressure through 150 PSIG standard. LCNG purifiers are ideal for large gas flow continuous duty service before the natural gas compressor. One tower purifies while the other regenerates. Systems are completely self-contained with pre-wired and pre-piped components.

Operation

Gas enters the prefilter which removes moisture and oil in liquid and aerosol form. The gas flows into left tower for drying, then through the afterfilter, preventing desiccant dust particle carry-over downstream.

While the left tower dries, a captive volume of gas flows through the right tower for regeneration. The blower moves the gas and the heater raises its temperature. The hot dry gas flows through the right tower and absorbs moisture to regenerate the desiccant. The moisture-loaded gas then flows through the gas cooler which condenses the moisture. The coalator removes the maximum amount of moisture from the gas. The right tower is cooled by turning the heater off. After a preset time, the towers switch roles.

Quality Features

 

Model

Inlet Capacity
SCFM/NM³HR
@50 PSIG/
3.5 BarG

In/out

Approximate
Shipping
Weight (lb/kg)

Dimensions (in/mm)

L

W

H

LCNG50

50/85

1/25.4 NPT

900/408

60/1524

60/1524

73/1854

LCNG75

75/128

1/25.4 NPT

1100/499

60/1524

60/1524

73/1854

LCNG100

100/170

1.5/38.1N NPT

1300/590

74/1626

60/1524

71/1803

LCNG150

150/255

1.5/38.1 NPT

2200/998

64/1626

60/1524

76/1930

LCNG200

200/340

2/50.8 NPT

2500/1134

69/1753

66/1676

86/2184

LCNG300

300/510

2/50.8 NPT

3000/1308

70/1778

70/1778

81/2057

LCNG400

400/680

3/76.2 FLG

3700/1678

80/2032

74/1880

86/2184

LCNG500

500/850

3/76.2 FLG

4000/1814

100/2540

80/3032

102/2591

LCNG600

600/1020

3/76.2 FLG

4400/1995

100/2540

80/3032

102/2591

LCNG800

800/1360

4/101.6 FLG

4800/2177

100/2540

80/3032

102/2591

LCNG1000

1000/1700

4/101.6 FLG

5700/2585

120/3048

86/2184

105/2667

Specifications subject to change without notice

 

rtborder
lftborder

SPECIALIZING IN AIR AND GAS PROCESSES SINCE 1980                                 210 FLATFORK ROAD, WARTBURG TN 37887  PHONE 423-346-6693  FAX 423-346-6835

For questions or comments about this web site please email the webmaster.

pioneer_air_systems_logo

“Non-Standard Equipment is Our Specialty”

facebook-icon
youtube-icon

Live Search
 

linkedin-icon
lftborder
rtborder
rtborder
lftborder

1-800-264-1AIR

PREMIERE DISTRIBUTORS