Aqua Saver series closed loop cooling systems
AS = Aqua Saver closed loop cooling systems
Pioneer's Aqua Saver Closed-loop systems eliminate water loss by evaporation and algae & bacteria problems. The Aqua Saver uses the ambient temperature to lower the the fluid temperature. If the ambient temperature is 90oF the unit can only cool down to 90oF.
- · Quality Features
- · Optional Features
- · Specifications
- · Pumping Stations and Data
- · Heat Exchanger Data
- · Reduce water usage by over 95% with an Aqua Saver system with Trim Cooler
- · Eliminate algae and bacteria-type problems.
- · No water consumption
- · Eliminate sewer charges
- · Adaptable to heat recovery
- · Eliminate scale and corrosion
- · Extend equipment life
- · Reduce maintenance cost
- · Reduce down time
- · Easy installation
- · Provide cooler water with Trim Cooler
- · Aqua Saver Packaged Systems (ASP series)
- · Aqua Saver heat exchanger
- · Fan cycling
- · Simplex or Duplex pumping station
- · Trim Cooler with water regulating valve
- · All prewired and prepiped on a single skid
- · Energy Saving Control Panel (Standard in ASP series and optional in AS series heat exchangers. Includes power-on/off switch, power-on indicator, fan motor starter(s), and fan cycling thermostat. Fan cycling saves energy and provides temperature control under varying load and ambient conditions.)
- · Packaged Aqua Saver systems
- · Freeze-Protector heat transfer fluid
- · Fan cycling
- · High temperature indicator and/or alarm
- · Pump failure indicator and/or alarm
- · Pump auto start (duplex pump only)
- · NEMA 4x, J.I.C., NEMA 7, NEMA 4 or NEMA 12
- · TEFC motors, fan(s) and pump(s)
- · Trim cooler and water regulating valve
- · Automatic fill
- · Three-way mixing valve for temperature control
- · No-flow shut down
- · Expansion tank sight glass
- · Low level shut down and indicator
- · Larger expansion tanks
- · Optional gauges
- · Pressure relief valve
AquaSaver Specifications
The packaged, single-skid, closed-loop system shall include…
Air-cooled Heat Exchanger
High-efficiency heat exchangers shall cool larger water flows with minimum pressure drop by using atmospheric air as the cooling medium. The cooling capacity to HP ration shall be maximum.
- Multi-circuit design shall have minimum pressure drop.
- Coil design shall allow even air distribution and therefore minimum pressure drop.
- For longevity materials shall be:
- Coil: aluminum fins, copper tubes
- Legs: galvanized steel
- Housing: aluminum
- Motors shall be direct-drive, amply sized to handle designed load conditions.
- Specially designed heavy-gauge aluminum blade fans shall be statically and dynamically balanced for vibration-free operation. Fans shall be protected with coated safety guards. Number of fans shall be _______, each _______ H.P. Fans shall cycle to save energy and provide temperature control. All connections shall be factory wired to the junction box on the housing exterior or to the control panel. The heat exchanger shall be Pioneer model___________
Simplex Pumping Station
Unit shall include a pump, expansion tank, starter, NEMA 1 control panel, power-on light, on/off switch, water-out pressure gauge, and water-out temperature gauge. The pumping station shall be Pioneer model__________
Trim Cooler
The Trim Cooler shall be tube and shell design. Tubes, shell and baffles shall be of rust-free materials: copper and/or brass. The trim cooler shall be Pioneer model______________
Options:
- · Duplex Pumping Station (in lieu of Simplex)
- Unit shall include two pumps, an expansion tank, two check valves (one for each pump), starters, NEMA 1 control panel, power-on light, on/off switch, water-out pressure gauge and water-out temperature gauge. Additionally, each pump shall be piped with two isolation valves, one on the suction side and one on the discharge side, so that either of the pumps can be removed from the piping system and replaced without having to shut down the system. All components shall be prepiped, wired and mounted on a skid.
The Duplex Pumping Station shall be Pioneer model _________________
- · Freeze Protector heat transfer fluid, _________ gallons.
- · NEMA 4 electrical
- · TEFC motors, fan(s)
- · TEFC motors, pump(s)
- · Water filter, Pioneer model _____________.