lftborder

Economical Contaminant Removal System

E = ECONOMICAL CONTAMINANT REMOVAL SYSTEM

 

Gas is filtered by an inlet scrubber before the gas to refrigerant (or glycol) heat exchanger to remove entrained particulates & liquids; and, to keep heat exchangers clean. The gas to refrigerant heat exchanger cools gas to 40oF before its compressed, which protects blower/compressor.

Gas compression raises the gas temperature, and lowers its relative humidity; which is desirable for most applications. Upon compression, the gas flows thru Moisture Evaporator (optional); where the gas is cooled and the moisture is evaporated. The system includes a "Back Pressure Control Valve" to control gas flow & pressure to the system outlet and return the excess gas. It's available as a factory integrated system; or, in two parts – Gas to Refrigerant Heat Exchanger and balance of the system.

DESIGN CONDITIONS

Gas Outlet Dew Point: 4oC / 40oF
Inlet temp: 120oF / 49oC (maximum)
Amb temp: 110oF / 43.3oC (maximum)
Gas flow thru SS (except blower)

Alarms:

  • · High DP across filter(s)
  • · High Liquid Level – Separators
  • · High Liquid Level – Filters
  • · High Refrigerant Pressure
  • · Low Refrigerant Pressure
  • · Low Inlet Gas Pressure
  • · Low Outet Gas Pressure

INSTRUMENTS / CONTROLS

Class 1, Group D & Division 1/2
Control Panel: NEMA 4X
Single Point Power Feed
Electro Mechanical / PLC Controls
Motor controls
Fusible Disconnect/ Circuit Breaker
Refrig. Suction Pressure Reading
Refrig. Disch. Pressure Reading
Dew Point Temperature Reading
Gas Inlet Temperature Reading
Gas Outlet Temperature Reading
Gas Inlet Pressure Reading
Gas Outlet Pressure Reading
Filter (s) Pressure Drop Reading

 

MODEL #

KW +/- 10%

Blower HP

SCFM @ 8" – 12" wc

In / Out Inch FLG

Approx Weight (LB)

Approx DIM (inch) L x H x W

E400*D

3

3

100

2"

2500 lb

72 x 48 x 96

E500*D

4

5

125

2"

3000 lb

72 x 48 x 96

E600*D

5

5

150

3"

3500 lb

84 x 72 x 96

E800*D

6

7.5

200

3"

4000 lb

96 x 72 x 96

E1000*D

8

10

250

3"

4500 lb

96 x 90 x 96

E1200*D

8

15

300

4"

5000 lb

120 x 90 x 100

E1600*D

10

20

400

4"

6500 lb

144 x 90 x 100

E2000*D

15

25

500

6"

8000 lb

168 x 90 x 100

E2500*D

15

30

625

6"

9500 lb

192 x 90 x 100

E3000*D

20

40

750

8"

11000 lb

216 x 90 x 104

E4000*D

30

50

1000

8"

14000 lb

240 x 90 x 108

E5000*D

40

60

1250

10"

17000 lb

264 x 90 x 108

E6000*D

40

75

1500

10"

20000 lb

388 x 90 x 108

E7000*D

50

100

1750

10"

23000 lb

312 x 90 x 112

E8000*D

60

100

2000

12"

26000 lb

336 x 90 x 112

E9000*D

70

125

2250

12"

29000 lb

360 x 90 x 120

E10000*D

80

150

2500

12"

30000 lb

384 x 90 x 120

 

rtborder

SPECIALIZING IN AIR AND GAS PROCESSES SINCE 1980                                 210 FLATFORK ROAD, WARTBURG TN 37887  PHONE 423-346-6693  FAX 423-346-6835

For questions or comments about this web site please email the webmaster.

pioneer_air_systems_logo

“Non-Standard Equipment is Our Specialty”

facebook-icon
youtube-icon

Live Search
 

linkedin-icon
lftborder
rtborder
rtborder
lftborder

1-800-264-1AIR

PREMIERE DISTRIBUTORS